“
“Poly(butylene terephalate) (PBT) and poly(butylene terephthalate-co-sebacate) (PBTS) copolymers containing 5 mol % and 10 mol % sebacate components (M-n = 12,700-14,600) were synthesized by polycondensation. The isothermal crystallization kinetics and melting behaviors after isothermal crystallization of the polymers were investigated
by differential scanning calorimetry (DSC). The equilibrium melting temperatures of the polymers were determined by Hoffman-Weeks equation. Analysis of the crystallization kinetic data using the Avrami equation showed that the introduction of sebacate enhanced the crystallization of PBT in PBTS. And the Avrami exponent n varies in the range of 2.16-3.68, indicating HDAC inhibitor that the isothermal crystallization follows two-and three-dimensional growth mechanism. Z-VAD-FMK The isothermal crystallization activation energies of
the polymers were also calculated by the Arrhenius equation. (C) 2011 Wiley Periodicals, Inc. J Appl Polym Sci 121: 735-742, 2011″
“Study Design. Biomechanical study.
Objective. To determine biomechanical forces exerted on intermediate and adjacent segments after two-or three-level fusion for treatment of noncontiguous levels.
Summary of Background Data. Increased motion adjacent to fused spinal segments is postulated to be a driving force in adjacent segment degeneration. Occasionally, a patient requires treatment of noncontiguous levels on either side of a normal level. The biomechanical forces exerted on the intermediate and adjacent levels are unknown.
Methods. Seven intact human cadaveric cervical spines (C3-T1) were mounted in a custom seven-axis spine simulator equipped Talazoparib price with a follower load apparatus and OptoTRAK three-dimensional tracking system. Each intact specimen underwent five cycles each of flexion/extension, lateral bending, and axial rotation under a +/- 1.5 Nm moment and a 100-Nm axial follower load. Applied torque and motion data in each axis of motion
and level were recorded. Testing was repeated under the same parameters after C4-C5 and C6-C7 diskectomies were performed and fused with rigid cervical plates and interbody spacers and again after a three-level fusion from C4 to C7.
Results. Range of motion was modestly increased (35%) in the intermediate and adjacent levels in the skip fusion construct. A significant or nearly significant difference was reached in seven of nine moments. With the three-level fusion construct, motion at the infra-and supra-adjacent levels was significantly or nearly significantly increased in all applied moments over the intact and the two-level noncontiguous construct. The magnitude of this change was substantial (72%).
Conclusion.