“There is an increasing demand for successful free tissue transfer, with postoperative Selleck MK-2206 monitoring of flaps a key to early salvage. Monitoring methods have ranged from clinical techniques to invasive options, of which two are particularly applicable to buried flaps (Cook-Swartz Doppler probe and microdialysis). The evidence for these options has been represented largely in separate cohort studies,
with no single study comparing these three techniques. We aim to perform this comparison in a single cohort of patients. A prospective, consecutive cohort study comparing clinical monitoring, microdialysis and the implantable Doppler probe was undertaken. In 20 patients receiving 22 flaps, 21 flaps were monitored with microdialysis, 18 flaps with clinical observation, and 21 flaps with the Cook-Swartz Implantable Doppler probe. Exclusion was based on applicability and availability intra-operatively. Efficacy was assessed through PLX 4720 sensitivity, specificity, positive, and negative predictive values. Nineteen of 22 flaps had no suspected anastomotic problems; 3 of 22 flaps were explored for anastomotic
problems, with two salvaged and one lost. The implantable Doppler and microdialysis were found to detect flap statistically earlier than clinical assessment, with microdialysis better at detecting flap compromise: 100% specificity (confidence 4��8C interval 31–100%) when compared to the implantable probe and clinical assessment
(67%: 13–98% and 33%: 2–87%, respectively). Each of the Cook-Swartz Doppler probe, microdialysis and clinical assessment was found suitable for monitoring in free tissue transfer. The implantable Doppler and microdialysis offer the potential for earlier detection of flap compromise. © 2014 Wiley Periodicals, Inc. Microsurgery, 2014. “
“Local or distant metastatic recurrence after therapy is observed in 20–30% of cases of head-and-neck cancer. An unfavorable course may occur after cervical lymph node dissection due to loss of immunoprotective lymph nodes in the head-and-neck region. To overcome this problem, we performed autologous lymph node transplantation from the groin after head-and-neck cancer resection and cervical lymph node dissection. The patient was a 63-year-old man with squamous cell carcinoma in the mesopharyngeal lateral wall. After tumor resection and right cervical lymph node dissection, a lymph node-containing superficial circumflex iliac artery perforator flap was transplanted from the left groin. Pathological examination showed that cancer had invaded the primary tumor tissue stump. Thus, radiotherapy (66 Gy) was performed for the residual tumor from days 28 to 84 after surgery.